Xiamen Caimore Communication Technology Co.,Ltd 2 F, 37#, Wanghai Road, Software Park 2, Xiamen,China (361009) ----------------------------------------------------------------------------------------------------------- RTU Analog output function Quick Operation Guide 1. RTU Cable Connection Please connect RTU to PC according to following steps first. 1. SIM card slot: Please ensure the RTU is powered off before pulling or plunging SIM card. 2. Power wire (PWR——black with white,GND——black); 3. RS232(D/RX——blue,D/TX——brown,GND——black): Please use this RS232 serial port to connect PC; USD forwarder to RS232 can be instead of if there is no RS232 serial port on PC. 4. Analog voltage V input (switch to up) or analog current I input (switch to down); 5. 8 analog input interface and (AG--Ground); 6. The cable connected to PC; 7. 2G/3G/4G antenna Please power on RTU after connection. 2. RTU analog input parameters configuration You can configure the parameters of analog input (analog voltage/current) by RTU WEB page or RTU management platform. Hereby will take an example of introducing how to configure analog voltage input on RTU WEB page and RTU Tel:+86 592 5901215 Web:1 www.caimore.com/emain.asp Xiamen Caimore Communication Technology Co.,Ltd 2 F, 37#, Wanghai Road, Software Park 2, Xiamen,China (361009) ----------------------------------------------------------------------------------------------------------management platform. 2.1 RTU WEB page configuration For example, please switch to the scale of V(voltage) side to select analog voltage (0-10V) 2.1.1 Enter into RTU WEB page 1. Open the browser and enter into the default IP address: 192.168.1.2; then fill in account name: admin, password: admin。 2. To choose English version on the left; 3. RTU IP address: Please change RTU’s IP address to avoid conflicts when you use cable connect RTU with switch. 2.1.2 Configure analog input parameters Tel:+86 592 5901215 Web:2 www.caimore.com/emain.asp Xiamen Caimore Communication Technology Co.,Ltd 2 F, 37#, Wanghai Road, Software Park 2, Xiamen,China (361009) ----------------------------------------------------------------------------------------------------------- 1. Click “RTU AD” on the left of menu bar; 2. Click” Edit” to enter the input parameters; 3. Select “YES” from drop-down box of “Enable” option; 4. Select “Voltage”/”V” from drop-down box of “Type”/”Unite” option. 5. Enter the top value of analog voltage into the “The relative voltage/current of the top range”. Tel:+86 592 5901215 Web:3 www.caimore.com/emain.asp Xiamen Caimore Communication Technology Co.,Ltd 2 F, 37#, Wanghai Road, Software Park 2, Xiamen,China (361009) ----------------------------------------------------------------------------------------------------------6. Enter the real value of analog voltage into the “The real voltage/current of the top range”. It is recommended to expand 1000 fold when setting the value; and minify 1000 fold. Otherwise too small value will lead to no change on collecting data. 7. Work type: To select the relative alarming mode, otherwise, no alarming. Alarming/ active report’s configure see as 2.1.3. 8. Alarm trigger conditions: Only valid to alarming. Whatever trigger conditions is, it will active report as long as the time is up. 9. The mobile phone number for alarming: up to 10 number, separated by “,". 10. Enter the alarm contents (no more than 140 bytes). 11. Click”Apply”; and then power off RTU first and power on again to reboot, or click “ reboot”, which is on the top right of this page. 2.1.3 Alarming/Active reporting configuration 2.1.3.1 Alarming configuration 1. 2. Click” RTU--Alarm” on the left of menu bar on the page. Alarm Way: Network alarming and SMS alarming. (currently, the module of MC2716, mu609, M305 support SMS alarming; the Tel:+86 592 5901215 Web:4 www.caimore.com/emain.asp Xiamen Caimore Communication Technology Co.,Ltd 2 F, 37#, Wanghai Road, Software Park 2, Xiamen,China (361009) ----------------------------------------------------------------------------------------------------------- 3. 4. 5. others are only support network alarming, 2G communication module can not support SMS due to no SMS port). To set the alarm interval time. Alarm times: if the value is 0, then RTU will send alarming info once time is up. The mobile phone number for alarming: up to 10 number, separated by “,". 6. Click “Apply”. Note: You can not query the alarm info according to RTU WEB page,
RTU Analoge output function Quick Operation Guide
温馨提示:如果当前文档出现乱码或未能正常浏览,请先下载原文档进行浏览。